Direct answer: EN 12464-1 sets maintained illuminance on the work plane — offices 500 lx (UGR ≤ 19, Ra ≥ 80), meeting rooms 300-500 lx, warehouse aisles and bulk storage 100-200 lx, packing/sorting 200-300 lx, precision assembly and inspection 500-750 lx (Ra 80-90). These are maintained values: plan for 20-30% more initial lumens to cover dirt and LED depreciation. Below is the zone-by-zone table and calculation method.
| Zone / task | Maintained lux | Max UGR | Min Ra |
|---|---|---|---|
| Office - writing, typing, screen work | 500 lx | 19 | 80 |
| Meeting / conference room | 300-500 lx | 19 | 80 |
| Technical drawing / CAD | 750 lx | 16 | 80 |
| Reception | 300 lx | 22 | 80 |
| Corridors / circulation | 100 lx | 28 | 40 |
| Warehouse storage - occasional access | 100 lx | 22 | 60 |
| Warehouse storage - frequent access | 200 lx | 22 | 60 |
| Packing / sorting station | 200-300 lx | 22 | 60-80 |
| General assembly / manufacturing | 300 lx | 22-25 | 60-80 |
| Fine assembly / inspection | 500-750 lx | 19 | 80-90 |
At the work plane — 0.75 m for desks, floor level for warehouse aisles. Lux at floor level in an office will be lower than at 0.75 m, so always state the measurement plane when checking compliance.
For a 100-200 lx warehouse zone, roughly 150-300 initial lumens per m² (before maintenance factor). At 200 lx maintained, a 2000 lm high-bay covers about 7-10 m² of floor area depending on mounting height and beam angle — run the lux calculation rather than using watts.
100 lx in a 200-300 lx task zone risks picking errors, rework and safety issues. Instead of lowering the whole area, light task stations locally (task lighting over benches) while keeping aisles at 100-150 lx — same budget, compliant result.
Yes — the standard applies to the installation, not the fixture. When replacing metal halide or fluorescent, keep the same maintained-lux target (see our metal-halide-to-LED guide for wattage conversion) and re-measure after retrofit, because LED optics change the light distribution.
Silamp — EN 12464-1 industrial lighting lux by zone: https://www.silamp.fr/pages/eclairage-industriel-nf-en-12464-1-combien-de-lux-pour-quelle-zone
LED World — EN 12464-1 indoor workplace lighting tables: https://ledworld.com/academy/en-12464-indoor-workplace-lighting
SmartQHSE — Lux level calculator and workplace guide: https://www.smartqhse.com/lux-level-calculator
Kingseng — Warehouse lighting lux requirements (2026): https://ksimpexp.com/warehouse-lighting-lux-requirements/
OKELI Lighting — commercial lighting manufacturer: https://www.okelilamp.com/professional-commercial-lighting-supplier/
Last updated: 2026-09-17